Single-Phase Pole-Mounted Distribution Transformer

Single-Phase Pole-Mounted Distribution Transformer
Details:
Oil-immersed pole-mounted transformer for rural, residential and small industrial distribution. Silicon-steel or amorphous cores, sealed tanks and 50/60 Hz designs are selected against the utility requirement and operating environment.
Send Inquiry
Description
Send Inquiry

Product Overview

A single-phase pole-mounted transformer is used where a compact distribution point can serve homes, farms, small businesses or a short low-voltage feeder. Mounting the transformer close to the load shortens the low-voltage run and can reduce line loss compared with a distant three-phase substation.

This range covers sealed oil-immersed designs with either silicon-steel or amorphous cores. Capacity, primary voltage, secondary voltage, losses, mounting dimensions and protection hardware should be confirmed against the utility's standard before production.

What to confirm before ordering

Primary and secondary voltage, phase arrangement and system frequency.

Required kVA and expected daily load profile.

Silicon-steel or amorphous core and the associated loss limit.

Pole span, mounting height, weight and required lifting points.

HV and LV bushings, fuse or cutout arrangement, surge protection and neutral connection.

Coastal, humid, dusty or high-altitude conditions and the destination's test requirements.

Technical specifications

Parameter Range / design option
Type Single-phase pole-mounted distribution transformer
Rated capacity 3–500 kVA
Primary voltage 2.4–35 kV, subject to project design
Secondary voltage 120–600 V, subject to project design
Frequency 50 Hz or 60 Hz
Core Silicon-steel wound core or amorphous-metal core
Cooling ONAN
Short-circuit impedance 2.5–4.0%, depending on rating and design
Installation Pole-mounted with tank, hanger brackets and bushings configured for the utility standard

Choosing between silicon steel and amorphous core

Silicon-steel cores are widely used where established utility practice, lead time and cost need to be balanced. Amorphous cores can lower no-load loss where the transformer will remain energised for long periods with light load. The choice should follow a life-cycle loss evaluation and the approved utility specification.

Pole mounting also creates mechanical requirements that do not appear on an electrical datasheet. Check the pole strength, bracket spacing, conductor loads and access for a lift truck before ordering. The final outline drawing should confirm the centre of gravity and lifting points.

Common questions

Can one unit supply a small three-phase motor?

A single-phase transformer should not be treated as a three-phase supply. If the load includes three-phase motors, specify a three-phase transformer or arrange a suitable phase-conversion system reviewed by the project engineer.

Can the transformer be supplied for 60 Hz?

Yes. The core and voltage design must be reviewed for the specified frequency; a 50 Hz nameplate cannot simply be relabelled for a 60 Hz network.

Which documents should come with the quotation?

Ask for the proposed outline drawing, loss values, tap arrangement, accessory list, routine-test scope and the certification or type-test evidence required for the destination.

Request a technical quotation

Send the voltage ratio, kVA, frequency, phase arrangement, pole details, required losses and destination. A utility specification or existing nameplate will help confirm the interfaces before production.

Hot Tags: Single-Phase Pole-Mounted Distribution Transformer, China Single-Phase Pole-Mounted Distribution Transformer manufacturers, suppliers, factory, 100 kva pole mounted transformer, pmt transformer, pole mounted transformer, power pole transformer, three phase pole mounted transformer, transformer pole

Send Inquiry