5000 KVA Power Transformer

5000 KVA Power Transformer
Details:
The 5000kVA oil-immersed power transformer is a core piece of equipment for 10kV/35kV power grids. It includes the SZ series on-load tap-changing model (±3×2.5%), which can adjust the voltage under load. It is highly efficient, energy-saving, and stable in operation. It is widely used in high-load scenarios such as industrial and mining, new energy, and urban power distribution to ensure stable power consumption on a large scale.
Send Inquiry
Description
Send Inquiry

Product Overview

 

As a key high capacity power distribution equipment in the 10kV/35kV power grid system, the 5000kVA oil immersed power transformer plays a crucial role in voltage conversion, power transmission, and efficient power distribution. With its core advantages of ultra large capacity output, high efficiency power conversion, and stable operation around the clock, the step up down transformer can be precisely adapted to various high load power consumption scenarios, including large industrial and mining enterprises, new energy power plants such as photovoltaic/wind power/energy storage, urban core power distribution nodes, large commercial complexes, data centers, and key infrastructure projects. It provides safe, continuous, and reliable power supply for large scale power demand and can flexibly cope with various complex power conditions.

 

5000kVA power transformer is a core piece of high capacity power distribution equipment in the 10kV/35kV power grid. Besides its fundamental functions of voltage conversion, power transmission, and distribution, its on load tap changing model (SZ series) offers significant advantages. This model supports a voltage regulation range of ±3×2.5%, allowing for flexible adjustment of the output voltage without shutdown while the transformer is operating under load. This effectively addresses complex conditions such as grid voltage fluctuations and load changes, ensuring the stability of the power supply voltage.

distribution transformer and power transformer
fender champ power transformer
for a power transformer
ge power transformers

 

Technical Specifications

 

Parameters

Technical Specifications

Model

Power Transformer

Rated capacity

5000kVA (customizable upon request)

Input voltage (high voltage)

6.6kV,10kV,11kV,20kV,35kV(Customization available upon request)

Output voltage (low voltage)

0.38kV,0.4kV(Customization available upon request)

Voltage regulation range

±5%,±2×2.5%(Customization available upon request)

Number of phases

Three phase (single phase can also be specified)

Frequency

50Hz/60Hz

Link Group

Dyn11,Yyn0,Yd11,Dyn5(Customization available upon request)

Winding material

Copper / Aluminum

No load loss

Meets national standards / IEC Level 1 / Level 2 energy efficiency

Load loss

Meets national standards / IEC Level 1 / Level 2 energy efficiency

No load current

Standard design values, low loss optimization

Temperature rise limit

≤60K (oil top layer)

Short circuit impedance

Customization available upon request

Cooling method

ONAN(Oil immersion and self cooling)

Insulation class

Grade A

Partial discharge

≤20pC (Standard requirement)

Implementation Standards

IEC,GB,JIS,ANSI,IEEE,UL

 

product-800-892

product-800-782

 

Product Advantages

 

  • Fully sealed structure, leak proof, maintenance free, and ensures stable and reliable long term operation.
  • Oil immersed insulation and heat dissipation provide strong overload capacity and adaptability to harsh outdoor environments.
  • Low loss and high efficiency significantly reduce operating energy consumption and operating costs.
  • Compact structure, small footprint, easy installation, and strong adaptability.
  • High cost effectiveness, long service life, and lower overall operation and maintenance costs.
  • Short circuit resistant and impact resistant, meeting the requirements for long term continuous load operation.
 

 

Oil Immersed Transformer FAQ

 

1. What is the short circuit withstand capability of your transformers?

Our designs meet IEC standards. Typical short circuit impedance is 4‑8%, and units pass certified short circuit tests to ensure no winding displacement or damage.

2. Do you provide remote monitoring features?

Yes. We can integrate oil temperature, winding temperature, oil level, and DGA sensors with remote communication (4G, RS485, or Ethernet) for smart grid applications.

3. What is the typical lead time for a custom oil immersed transformer?

Standard designs: 4‑6 weeks. Custom units (special voltage, impedance, or accessories): 8‑12 weeks, depending on factory load and complexity.

 

Product Information and Certificates

 

We provide the following complete technical documentation and quality documents:

• Material Safety Data Sheet (MSDS)

• Factory Test Report

• Certificate of Conformity

• Product Certificate

• Product Installation and Operation Manual

 

Hot Tags: 5000 kva power transformer, China 5000 kva power transformer manufacturers, suppliers, factory, aluminum winding power transformer, marine power transformer, oil immersed power transformer, resin encapsulated power transformer, shell form power transformer, unit substation transformer