Product Overview
1000kVA dry type transformer features epoxy resin cast insulation and boasts several key characteristics: low loss (no load loss reduced by over 20%, excellent energy efficiency, economical operation, and maintenance free); low partial discharge (the resin mixture utilizes advanced foreign mixing methods and vacuum degassing technology to ensure uniform mixing and complete elimination of air bubbles, resulting in extremely low partial discharge, controllable below 5pc); and both high and low voltage coils are cast under vacuum and pressure, providing both full encapsulation and inter turn impregnation of the resin insulation.
1000kVA dry type transformer casting has a dense, cured structure that is flame retardant, explosion proof, and environmentally friendly. The insulating materials, such as fiberglass, used in the winding coils are self extinguishing, preventing arcing during short circuits, and the resin does not produce toxic or harmful gases under high heat. High mechanical strength: The filler filled resin results in a small difference in the coefficient of expansion within the casting, low curing shrinkage, low internal stress, and high hardness of the cured product. Pre formed reinforcing materials are placed within the epoxy resin encapsulation layers on the inner and outer surfaces of the high and low voltage coils, creating a dense structure similar to reinforced concrete. Therefore, its mechanical strength is even greater than that of pure epoxy resin, enabling it to withstand sudden short circuit electrodynamic forces without damage.




Technical Specifications
|
Number |
technical grade |
|
Model number |
Drying type converter for drying oil |
|
Constant capacity |
1000kVA (Adjustable demand system) |
|
Imported electricity (Gaogu) |
6.6kV,10kV,11kV,20kV,22kV,22.9kV,35kV(Adjustable demand system) |
|
Export electricity (low pressure) |
0.38kV,0.4kV,(Adjustable demand system) |
|
Voltage regulation range |
±5%,±2×2.5%,(Adjustable demand system) |
|
Number of phases |
Three phase(Adjustable demand system) |
|
Frequency |
50Hz/60Hz |
|
Link Group |
Dyn11,Yyn0,Yd11,Dyn5,YNd11(Adjustable demand system) |
|
Winding material |
Aluminum/Copper |
|
No load loss |
(Adjustable demand system) |
|
Load loss |
(Adjustable demand system) |
|
No load current |
(Adjustable demand system) |
|
Temperature rise limit |
100K,125K(Corresponding to F/H class insulation)(Adjustable demand system) |
|
Short circuit impedance |
(Adjustable demand system) |
|
Cooling method |
AN (natural cooling) or AF (forced air cooling) |
|
Insulation class |
Class F (Class H optional) |
|
Partial discharge |
≤5pC |
|
Implementation Standards |
IEC,GB,JIS,ANSI,IEEE,UL |
Usage scenario


Dry Type Transformer FAQ
1. What's the difference between dry type and oil immersed transformers? Which one should I choose?
Dry type is fire safe, maintenance free, and ideal for indoor use. Oil immersed costs less and suits outdoor applications. Choose dry type for indoor, fire sensitive areas.
2. Does a dry type transformer need regular maintenance? How long does it last?
Almost no maintenance – just occasional dust cleaning. Lifespan is typically 25–30 years under normal indoor operation.
3. What capacity, voltage, and custom options do you offer?
Capacities from 30kVA to over 10,000kVA, primary voltage up to 35kV, secondary 0.4kV/0.69kV. Custom design, enclosure, paint, and logo available.
Product Information and Certificates
We provide the following complete technical documentation and quality documents:
• Material Safety Data Sheet (MSDS)
• Factory Test Report
• Certificate of Conformity